  • Structerre Consulting Engineers | Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany | IS YOUR ON-SITE WASTE SYSTEM COMPLIANT, SAFE & EFFICIENT?
    At Structerre we have over 10 years experience in carrying out both Site and Soil Assessments and also designing Effluent Disposal systems We are familiar with industry leading effluent treatment products systems and take pride in offering quality designs that work best for your individual project complying with local council and Australian standards Contact Us Today We can provide the following Site and soil assessments including soil classification Effluent disposal design layout and details Calculations and reports to comply with relevant Australian and local council standards Provide a complete package to submit to council for approval which includes all of the above Why Choose Us For Your Effluent Disposal Design Over the years our company has worked with Structerre for a variety of projects and more recently we commissioned them to design an effluent system for a rural project During the design process all of our questions were answered in a friendly and helpful manner and the final design documentation was of high quality and detail James Bentham Director of Begbie Bentham Design Build We can Lean on over 10 years of experience Guarantee familiarity with industry leading products Provide tailored solutions for each project Offer quick turnaround times Service a wide range of suburbs Ensure safe sanitation and disposal Locations WA Perth Bunbury Albany Geraldton QLD Brisbane NSW Sydney VIC Melbourne Geelong Cranbourne Latest News Requirements for Building in Bushfire Prone Areas The WA State Government has now passed legislation which means if you are building a home or performing construction work in a designated bushfire prone area you will be required to undertake a Bushfire Attack Level BAL assessment Based on the results of the assessment you will need to comply with the bushfire construction requirements of the Building Code of Australia BCA Read More 22 01 2016

    Original URL path: http://www.structerre.com.au/is-your-on-site-waste-system-compliant-safe-efficient (2016-02-17)
    Open archived version from archive


  • Structerre Consulting Engineers | Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany | Culture | News | NATA Accreditation Achieved for our Perth Laboratory
    D29 STr100 Footing Detail Patented Share This Sign Up for our Newsletter Location Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany Geelong Our Perth laboratory has achieved worldwide accreditation from the National Association of Testing Authorities Australia Our standards and proficiencies have met those of the international standard ISO IEC 17025 formally recognising our continuous high quality of service and technical competence provided to our clients NATA is one of the largest laboratory accreditation bodies in the world and is responsible for the accreditation of laboratories inspection bodies calibration services producers of certified reference materials and proficiency testing scheme providers throughout Australia Obtaining this accreditation gives customers and regulators the knowledge that material specifications are being met and our laboratory operations and equipment are safe and dependable An assessment team visited our laboratory to inspect our documents methods and equipment and thoroughly evaluated all elements of our operations This included technical competence training and supervision of staff quality control and proficiency testing suitability and maintenance of equipment as well as the physical environment in which activities are performed Surveillance visits will be performed every 18 months to ensure continued compliance with requirements and maintain our standing with NATA Now that accreditation has been awarded our laboratory is internationally recognised for continued technical competence giving clients further assurance that our testing is carried out to the highest standards Form more information regarding our NATA accreditation scope follow this link to the NATA website Back to News Listings Have questions for us Contact us and we can help Locations WA Perth Bunbury Albany Geraldton QLD Brisbane NSW Sydney VIC Melbourne Geelong Cranbourne Latest News Requirements for Building in Bushfire Prone Areas The WA State Government has now passed legislation which means if you are building a home or performing construction work in a

    Original URL path: http://www.structerre.com.au/news/nata-accreditation-achieved-for-our-perth-laboratory (2016-02-17)
    Open archived version from archive

  • Structerre Consulting Engineers | Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany | Pre Purchase Inspections Perth
    the Christmas break An engineer was on site within 48 hours and a verbal report was given the day of the pre purchase inspection Alternative action was discussed and a written report and remedial specification received as promised immediately after the Christmas break On short notice a pre purchase inspection was carried out during the remedial work in Roleystone Perth What was also impressive is that the engineer was prepared to listen to alternative methods from the builder I would have no hesitation in recommending Structerre as the pre purchase inspection work in Perth was carried out immediately and at a reasonable cost Nicole Gardiner Gardiners Real Estate Pty Ltd Finding a structural problem with your new home after you have purchased it is disappointing and can sometimes be costly With our clients wishes in mind we perform an extensive visual pre purchase inspection of the residence to determine if there are any structural defects that require remedial action We are able to determine in the pre purchase inspection if the defects are in fact structural unlike a building inspector saving you the cost of two reports and giving you peace of mind with your purchase Book a pre purchase inspection with Structerre today Our ink signed reports include Photographs of outlined defects Overview of the visual structural elements Comments on the defects The option to gain solutions to rectify issues We inspect but are not limited to Interior and exterior Roof cover and structure Footings Structural cracks Get Instant Quote Book Online Locations WA Perth Bunbury Albany Geraldton QLD Brisbane NSW Sydney VIC Melbourne Geelong Cranbourne Latest News Requirements for Building in Bushfire Prone Areas The WA State Government has now passed legislation which means if you are building a home or performing construction work in a designated bushfire

    Original URL path: http://www.structerre.com.au/make-sure-your-house-is-structurally-sound-before-you-buy (2016-02-17)
    Open archived version from archive

  • Structerre Consulting Engineers | Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany | Projects | West End Apartments - WA
    bearing concrete tilt up wall panels and non load bearing stud framed walls roof trusses and deltacore slabs for the flooring system Our team worked with the architect to ensure that the large cantilevers which were an important part of the project could be achieved while incorporating the precast construction methodology Our team also conducted a geotechnical investigation to provide a site classification and recommendations for earthworks and stormwater drainage Our team assessed the ground profile and groundwater conditions earthquake site factors permeability rates suitability of existing material as controlled fill and provided recommendations on site preparation suitable foundation systems and retaining wall design We performed EFCPT testing to 10m push probe boreholes to 2 5m hand auger boreholes insitu percolation tests and PSP tests Our energy team worked closely with Builton to ensure the commercial and residential buildings were constructed to be energy efficient and thermally comfortable for all occupants The first floor residential units being located directly above the ground floor car park resulted in these units performing worse due to increased heat loss through the exposed suspended floor Insulating these exposed floors eliminated this issue allowing the building to perform efficiently The residential units collectively achieved a star rating of 6 stars with individual units achieving not less than 5 stars This complex project was successfully turned around in 5 days to meet the client s urgent brief Download Profile Back to Case Study Listings Project Details Team Structural Geotechnical Energy Assessment Project Title West End Apartments Location Blythe Avenue Yokine WA Client Builton Group Date 15 12 2015 Project Gallery Have questions for us Contact us for help now Locations WA Perth Bunbury Albany Geraldton QLD Brisbane NSW Sydney VIC Melbourne Latest News Requirements for Building in Bushfire Prone Areas The WA State Government has now

    Original URL path: http://www.structerre.com.au/projects/west-end-apartments-wa (2016-02-17)
    Open archived version from archive

  • Structerre Consulting Engineers | Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany | Projects | Halcyon Glades Recreational Club
    enjoy Structerre was contracted to perform all structural works for the Halcyon Glades Recreational Club Our team was involved in the concept stage and has since provided the detailed structural design and compliance inspection We worked closely with the project architect on the rammed earth feature wall detailing and exposed timber feature trusses The incorporation of rammed earth walls was an interesting part of the project and our team worked hard to get the detailing perfect for the client Strong communication and regular meetings helped reach a satisfactory outcome with the timber feature trusses Download Profile Back to Case Study Listings Project Details Team Structural Project Title Halcyon Glades Recreational Club Location Ardrossan Road Caboolture North QLD Client Halcyon Developments No 5 Pty Ltd Date 10 12 2015 Project Gallery Have questions for us Contact us for help now Locations WA Perth Bunbury Albany Geraldton QLD Brisbane NSW Sydney VIC Melbourne Latest News Requirements for Building in Bushfire Prone Areas The WA State Government has now passed legislation which means if you are building a home or performing construction work in a designated bushfire prone area you will be required to undertake a Bushfire Attack Level BAL assessment Based on

    Original URL path: http://www.structerre.com.au/projects/halcyon-glades-recreational-club (2016-02-17)
    Open archived version from archive

  • Structerre Consulting Engineers | Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany | Projects | Energy Assessment - Verification Using a Reference Building - Double Storey
    floor roof cover with Anticon 55 approx 80m2 When Structerre assessed this dwelling through the VURB method the following heating and cooling energy loads applied Reference Dwelling Heating 43 0 MJ m2 Cooling 30 4 MJ m2 Proposed Dwelling Heating 60 3 MJ m2 Cooling 14 9 MJ m2 As the proposed house had heating and cooling energy loads which were equal to or less than the reference building the proposed building was deemed compliant through V2 6 2 2 NCC 2013 The proposed building was compliant based on the builder s standard specification R3 5 to ceilings Generic single clear glass Value 6 57 SHGC 0 74 Sealed exhaust fans No cavity insulation or upgraded glazing was required for compliance This assessment method has been carried out in accordance with the V2 6 2 2 a b c d e requirements by a Structerre qualified person using NatHERS accredited software Even though this project is not a 6 star energy efficient dwelling it will still meet BCA V2 6 2 2 energy compliance The reduced construction costs are based on 127m2 x 15 m2 cavity insulation 80m2 x 10 m2 Anticon 55 and 5m2 x 150 m2 Low E Clear glazing This equates to a potential cost saving of 3 455 Download Profile Back to Case Study Listings Project Details Team Energy Assessment Project Title erification Using a Reference Building Double Storey Location Various Client Various Date 16 06 2015 Project Gallery Have questions for us Contact us for help now Locations WA Perth Bunbury Albany Geraldton QLD Brisbane NSW Sydney VIC Melbourne Latest News Requirements for Building in Bushfire Prone Areas The WA State Government has now passed legislation which means if you are building a home or performing construction work in a designated bushfire prone area you

    Original URL path: http://www.structerre.com.au/projects/energy-assessment-verification-using-a-reference-building-double-storey (2016-02-17)
    Open archived version from archive

  • Structerre Consulting Engineers | Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany | Projects | Energy Assessment - Verification Using a Reference Building - Single Storey
    heating and cooling energy loads which were equal to or less than the reference building the proposed building was deemed compliant through V2 6 2 2 NCC 2013 The proposed building was compliant based on the builder s standard specification R4 1 to ceilings Generic single clear glass Value 6 57 SHGC 0 74 Sealed exhaust fans No cavity insulation or upgraded glazing was required for compliance This assessment method has been carried out in accordance with the V2 6 2 2 a b c d e requirements by a Structerre qualified person using NatHERS accredited software Even though this project is not a 6 star energy efficient dwelling it will still meet BCA V2 6 2 2 energy compliance The reduced construction costs are based on 73m2 x 15 m2 cavity insulation This equates to a potential cost saving of 1 095 Download Profile Back to Case Study Listings Project Details Team Energy Assessment Project Title Verification Using a Reference Building Single Storey Location Various Client Various Date 16 06 2015 Project Gallery Have questions for us Contact us for help now Locations WA Perth Bunbury Albany Geraldton QLD Brisbane NSW Sydney VIC Melbourne Latest News Requirements for Building

    Original URL path: http://www.structerre.com.au/projects/energy-assessment-verification-using-a-reference-building-single-storey (2016-02-17)
    Open archived version from archive

  • Structerre Consulting Engineers | Perth Brisbane Sydney Melbourne Bunbury Geraldton Albany | Projects | Hemingway Residences
    The portal columns also breached the party walls which made it almost impossible to achieve the required Fire Resistance Level Structerre Melbourne in cooperation with the Sydney office advised to replace the initial design with a waffle pod slab design supported by screw piles We were able to achieve building stability through conventional bracing and PFC SHS portal frames that did not breach the party walls The project also faced some challenges during site preparation On many areas of the site rock was encountered within a few 100mm from the ground surface We advised that in the rocky areas excavation to the rock surface only was suitable Our new design also allowed less excavation saving a lot of time An incorrectly sighted oak tree on town planning documentation became an obstacle as the edge of the slab was planned only 2 2m away from the centre of the tree trunk while no excavation was permitted within an 3 5m radial zone Structerre delivered a foundation design that enabled cantilevering of the building hence no excavation was required within the protection zone of the oak Brian Nasr Structerre s project manager on the Hemingway Residences worked hard to achieve the best possible solutions and exceed the clients expectations We were consulted on this project at a very late stage yet we managed to meet every deadline and received many praises from the builder and developer regarding our prompt delivery Download Profile Back to Case Study Listings Project Details Team Structural Geotechnical Commercial Infrastructure Project Title Hemingway Residences Location Heidelberg Road Alphington VIC Client Madisson Projects Date 15 05 2015 Project Gallery Have questions for us Contact us for help now Locations WA Perth Bunbury Albany Geraldton QLD Brisbane NSW Sydney VIC Melbourne Latest News Requirements for Building in Bushfire Prone Areas

    Original URL path: http://www.structerre.com.au/projects/hemingway-residences (2016-02-17)
    Open archived version from archive



  •