archive-au.com » AU » I » INSULCO.COM.AU

Total: 192

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Domestic Roofers
    Domestic Roofers insulation services for specifier builder project owner commercial trade commercial roofers domestic roofers HVAC commercial fit out homeowner retrofit building certifier Builder commercial roofers domestic roofers HVAC interior commercial fit out Products residential thermal acoustic building blanket roofing accessories commercial acoustic insulation reflective foil insulation laminates HVAC acoustic industrial armaflex pipe sheet roll tapes accessories Product Selector nearest retailer nearest installer downloads calculators Home Trade Domestic Roofers Domestic Roofers Fletcher Insulation has the full range of domestic under roof insulation solutions Permastop building blanket is the leading brand in roofing blanket which is available in a range of thicknesses and thermal R values to meet your metal roofing project needs Additionally Fletcher Insulation has available the full Sisalation foil range for all metal and tile roof applications back to top Supporting partners I am Specifier I am a Builder I am Trade I am a Homeowner I am a Building Certifier Sign up for all the latest news and promotions find your nearest retailer Fletcher Insulation Pty Ltd Head office find your nearest installer 600 Woodstock Avenue Rooty Hill 2766 NSW call 1300 654 444 insulation for specifier builder trade homeowner retrofit building certifier products residential thermal acoustic

    Original URL path: http://www.insulco.com.au/trade/domestic-roofers (2015-10-07)
    Open archived version from archive


  • Heating, Ventilation and Air Conditioning
    Selector nearest retailer nearest installer downloads calculators Home Trade Heating Ventilation and Air Conditioning Heating Ventilation and Air Conditioning Fletcher Insulation has an exclusive range of glasswool products to meet the requirements of internal and external duct work insulation and energy efficiency Fletcher Insulation delivers value in the following ways Products are delivered on time and in full Products are compliant to Australian Standards Products cut superior giving straighter and firmer edges Products are more solid giving a durable and crush resistant finish Wide range of products available whatever the application Fletcher Insulation has an extensive Australia wide delivery service We know how important it is for you to get product when you want it so we guarantee next day delivery for stocked items and if required can organise same day delivery for you Even with our extensive product range sometimes standard products won t suffice and a unique solution is required Our Technical Service Managers are experienced insulation professionals available to give advice on the most efficient economic solution to meet your needs These solutions deliver value because they are tailored to your specific requirement back to top Supporting partners I am Specifier I am a Builder I am

    Original URL path: http://www.insulco.com.au/trade/HVAC (2015-10-07)
    Open archived version from archive

  • Interior Commercial Fit Out
    Out insulation services for specifier builder project owner commercial trade commercial roofers domestic roofers HVAC commercial fit out homeowner retrofit building certifier Builder commercial roofers domestic roofers HVAC interior commercial fit out Products residential thermal acoustic building blanket roofing accessories commercial acoustic insulation reflective foil insulation laminates HVAC acoustic industrial armaflex pipe sheet roll tapes accessories Product Selector nearest retailer nearest installer downloads calculators Home Trade Interior Commercial Fit Out Interior Commercial Fit Out Fletcher Insulation offers a wide range of commercial acoustic products specifically designed to suit internal partition and fit out applications The range provides the trade with wide range of acoustic options available from our national distribution network Feel free to also contact our Technical Services Team to find the most suitable system for your application on 1800 000 878 back to top Supporting partners I am Specifier I am a Builder I am Trade I am a Homeowner I am a Building Certifier Sign up for all the latest news and promotions find your nearest retailer Fletcher Insulation Pty Ltd Head office find your nearest installer 600 Woodstock Avenue Rooty Hill 2766 NSW call 1300 654 444 insulation for specifier builder trade homeowner retrofit building certifier

    Original URL path: http://www.insulco.com.au/trade/interior-commercial-fit-out (2015-10-07)
    Open archived version from archive

  • Homeowner and Retrofit
    instructions on the reverse of the product s packaging or click here Tools Required Curved blade knife with plastic handle nonconductive handle For high density batt blanket a serrated knife with a plastic handle is recommended Knife holster to quickly access the knife Industrial strength ladder Batt poker s a batt poker is an essential item of equipment This allows you to position batts into inaccessible ceiling locations Ensure that the batt poker handle is made from non conductive material such as wood or plastic Claw hammer Staple gun Tape measure Cordless drill metal framing Safety eye wear Safety shoes Before you commence Turn off the power at the fuse box before commencing the installation Ensure you place a warning tag to prevent power being restored prior to completion of the install Be aware that your electrical appliances will not be operational during this time Use only Pink Wall Batts recommended according to the type and thickness of the stud Installation guidance Brick Veneer Friction fit the batts into the wall frames ensuring there are no gaps between the batts and studs or noggins It is important that the batts are secured so they cannot fall into the cavity or come in contact with the outer brickwork allowing moisture to pass from the exterior wall to the internal lining Wall wrap or long lasting string twine should be fixed across the exterior face of the frame before installing the batts from the inside Where string twine is used twine should be fixed between each set of studs from the top to the bottom running parallel with the studs Where two lengths are used they should be evenly spaced Ensure that the batts do not protrude past the stud and fit snugly including where insulation batts are around water pipes or other rigid obstructions in the wall Fibre Cement or Weatherboard Cladding A breather low vapour barrier wall wrap or building paper must be used so as not to cause moisture build up Butt the batts closely together to ensure there are no gaps left at joints Offcuts may be used to fill small spaces to ensure a complete coverage Cavity Brick Walls Double Brick Pink Batts insulation is not recommended for use in cavity brick construction CAUTION When insulating around downlights or where recessed ceiling fixtures are present Leave a minimum clearance of 50mm from the body of heat emitting fixtures such as downlights exhaust fans and flues Cut a hole in the batt to suit the location of the fixture Pink Ceiling Batts have been independently tested and passed the requirements of AS3999 Appendix B Do not use small pieces of batts to form part of the barrier around a fixture as these pieces could dislodge and cover the fixture potentially overheating faulting the device Locate transformers on the ceiling plaster with a minimum gap of 50mm around the device alternatively place the transformer onto the glasswool or rockwool batt Exhaust fans typically vent vertically to the roof space Leaving a clearance of at least 50mm insulate around the perimeter of the fixture and ensure a piece of insulation batt does not stop a fan blade from turning as this can overheat and burn out the device PINK FLOOR BATTS Safety WARNING If the electrical wiring is connected to the meter box before commencing installation ensure the power is isolated and tagged Prior to commencing work check clearances for access points and crawl spaces in the sub floor WARNING Prior to commencing work check clearances for access points and crawl spaces in the sub floor CAUTION Keep a minimum clearance of 50mm from heat emitting devices Electric cables and equipment partially or completely surrounded with bulk thermal insulation may overheat and fail This applies to wiring installed prior to 1989 Refer to AS3999 1992 including Amendment 1 Section 2 6 for details Cabling post 1989 continuous electrical cabling 240 volts cannot be fully surrounded by the insulation for a length greater than 300mm In runs greater than 300mm the electrical wiring must be touching a timber stud or the plaster lining For comprehensive details please refer to the installation instructions on the reverse of the product s packaging Tools Required Curved blade knife with plastic handle non conductive handle For high density batt blanket a serrated knife with a plastic handle is recommended Knife holster to quickly access the knife Industrial strength ladder Claw hammer P2 dust mask Staple gun Knee pads Torch and spare batteries Tape measure Safety eye wear Safety shoes Hammer Cordless drill metal framing Before you commence Before entering the crawl space ensure your surrounding areas are safe from any spiders insects and or biological hazards Turn off the power at the fuse box before commencing the installation Ensure you place a warning tag to prevent power being restored prior to completion of the install Be aware that your electrical appliances will not be operational during this time Installation guidance New floor fitting batts to the floor joists before flooring is fitted NOTE the product s retention strapping is installed first the batts are then laid on top T o begi n th e installation th e retentio n stra p shoul d b e staple d o r fastene d securel y o n th e oute r sid e an d th e underneat h base o f th e joist The n ru n th e tap e unde r th e botto m fac e o f th e joist s an d onc e agai n stapl e o r faste n t o th e oute r fac e o f th e next jois t a s before I f th e jois t i s 90m m deep th e tap e run s straigh t acros s th e gap I f th e jois t i s 100 m m deep the n th e tape shoul d b e staple d o n th

    Original URL path: http://www.insulco.com.au/homeowner/homeowner-retrofit (2015-10-07)
    Open archived version from archive

  • Building Certifier
    air leakage will reduce thermal performance of reflective foil insulation Performance claims guidelines by type of insulation e g Material R for batts and loose fill Total R for foil Required labelling product disclosures and safety information to comply with this Standard AS NZS 4200 1 1994 1 Pliable building membranes and underlay s Material is relevant for reflective insulation materials and is cross referenced in AS NZS 4859 1 Fire Standards AS NZS 4BS9 1 DOES NOT cover insulation fire properties by type The main reference fire performance tests are AS1530 1 non combustibility the most stringent test AS1530 2 surface fire performance for facings and foils and As1530 3 general indices for batts and loose fill Compliance testing In order to demonstrate compliance with AS NZS 4BS9 1 testing must be performed by a recognised laboratory relevant to this Standard Test results are valid for 5 years In recent times noncompliance with this requirement has increased A provision of this Standard is that copies of test reports and where required calculation reports are to be made available on request for verification Installed insulation Correct installation is all Important to achieving the claimed thermal performance Installing Insulation can be classified into distinct sections 1 Bulk insulation a Batts and blankets e g glasswool Rockwool polyester sheep wool b Loose fill materials e g macerated paper cellulose fibre blown glasswool and granulated Rockwool 2 Reflective foils a Reflective Insulations e g single and double sided fall laminates bubble wrap foam foil faced wrap 3 Others a Rigid Boards b Foam insulation Insulation Installation standards for bulk insulations AS 3999 992 Thermal insulation of dwellings Bulk insulation installation requirements is the current Standard for bulk insulation installations Provisions in this standard cover the importance of Site Inspections prior to proceeding wit

    Original URL path: http://www.insulco.com.au/building-certifier/fletcher-building-certifier (2015-10-07)
    Open archived version from archive

  • Calculators
    a fluid that will contact the inside surface it should be assumed that the internal surface temperature is equal to the operating temperature and the appropriate selection made in the drop down menu Mean Temperature oC Thermal Conductivity W mK Semi Rigid High Density High Temp 20 0 032 0 031 50 0 038 0 035 100 0 050 0 045 150 0 063 0 053 200 0 080 0 065 250 0 080 Thickness required The insulation k value should be determined for the design insulation type and appropriate mean temperature A table of typical k values appear below for two common Insulco products used in industrial applications Surface temperatures may be used for Operating and or Ambient temperatures providing the appropriate selection is made for the surface condition in the drop down menus In cases where the operating temperature is a fluid that will contact the inside surface it should be assumed that the internal surface temperature is equal to the operating temperature and the appropriate selection made in the drop down menu Mean Temperature oC Thermal Conductivity W mK Semi Rigid High Density High Temp 20 0 032 0 031 50 0 038 0 035 100 0 050 0 045 150 0 063 0 053 200 0 080 0 065 250 0 080 Mean temperature is the average of the internal and external surface temperatures Acousti Max insulco acousti max acoustic prediction software Insulco Acousti Max is the most sophisticated program for the prediction of noise transmission loss in walls and floor ceiling systems An essential tool for estimating the Transmission Loss TL over a range of frequencies as well as Weighted Sound Reduction Indices of STC and Rw as required by the Building Code of Australia Acousti Max comes packed with features and functions With extensive

    Original URL path: http://www.insulco.com.au/calculators/ (2015-10-07)
    Open archived version from archive

  • Fletcher Insulation® Australia's Leading Insulation Manufacturer
    roll tapes accessories ceiling tiles regulations standards about us contact us downloads insulation services for specifier builder project owner commercial trade commercial roofers domestic roofers HVAC commercial fit out homeowner retrofit building certifier Welcome to Fletcher Insulation Australia s leading insulation company supplying Australia s favourite brands of insulation Our Brands View all brands Supporting partners I am Specifier I am a Builder I am Trade I am a Homeowner

    Original URL path: http://www.insulco.com.au/index.html (2015-10-07)
    Open archived version from archive

  • Products
    Selector nearest retailer nearest installer downloads calculators Home Products Products residential thermal acoustic building blanket roofing accessories commercial acoustic insulation reflective foil insulation laminates HVAC acoustic industrial armaflex pipe sheet roll tapes accessories back to top Supporting partners I am Specifier I am a Builder I am Trade I am a Homeowner I am a Building Certifier Sign up for all the latest news and promotions find your nearest retailer

    Original URL path: http://www.insulco.com.au/products/index.html (2015-10-07)
    Open archived version from archive



  •